AIHW logo

METEOR logo

Our sites
AIHW GEN Aged Care Data Aboriginal and Torres Strait Islander
Health Performance Framework
Indigenous Mental Health and
Suicide Prevention Clearinghouse
Australian Mesothelioma Registry Housing data Regional Insights for Indigenous Communities
Contact FAQs

Site Navigation

  • Find metadata
    • Find metadata
    • Getting started
    • Data set specifications
    • Indicator sets
    • Data quality statements
    • Data dictionary archives
  • Metadata management
    • Metadata management
    • Data standards
    • Registration authorities
    • Registration statuses
  • How to use METEOR
    • How to use METEOR
    • First steps
    • Using My Page
    • Downloading and printing
    • FAQs
    • About METEOR
  • Learn about metadata
    • Learn about metadata
    • Metadata explained
    • How to create metadata
    • Metadata development resources
Your session is about to end!
Your session will expire at [TIME]
Select Extend at the top right corner or you will be logged out

Third and Fourth Degree Perineal Tears Clinical Care Standard: 3a-Proportion of women who had an instrumental vaginal birth using vacuum

Indicator Attributes

Identifying and definitional attributes

Metadata item type:Help on this termIndicator
Indicator type:Help on this termIndicator
Short name:Help on this term3a-Proportion of women who had an instrumental vaginal birth using vacuum
METEOR identifier:Help on this term728359
Registration status:Help on this term

Australian Commission on Safety and Quality in Health Care, Standard 20/04/2021

Description:Help on this term

The proportion of women who had an instrumental vaginal birth using vacuum.

Indicator set:Help on this term
Clinical care standard indicators: Third and Fourth Degree Perineal Tears

        Australian Commission on Safety and Quality in Health Care, Standard 20/04/2021

Collection and usage attributes

Population group age from:Help on this term

18 yrs or older

Computation description:Help on this term

The proportion of women who had an instrumental vaginal birth using vacuum.

Presented as a percentage.

Computation:Help on this term

(Numerator ÷ Denominator) x 100​

Numerator:Help on this term

Number of women who had an instrumental vaginal birth using vacuum.

10th Edition ACHI codes

CodeDescription
90469-00 Vacuum assisted delivery
Numerator data elements:Help on this term
Data Element / Data Set

Episode of admitted patient care—procedure, code (ACHI 10th edn) NNNNN-NN

Denominator:Help on this term

Number of women who had a vaginal birth.

Include separations where an outcome of delivery was recorded using the ICD codes in Table A, and a caesarean delivery was not recorded (Table B).

Table A: ICD-10-AM codes for delivery outcome

CodeDescription
Z37.0Single live birth
Z37.1Single stillbirth
Z37.2Twins, both liveborn
Z37.3Twins, one liveborn and one stillborn
Z37.4Twins, both stillborn
Z37.5Other multiple births, all liveborn
Z37.6Other multiple births, some liveborn
Z37.7Other multiple births, all stillborn
Z37.9Outcome of delivery, unspecified

Table B: ACHI codes for caesarean section

CodeDescription
16520-00Elective classical caesarean section
16520-01Emergency classical caesarean section
16520-02Elective lower segment caesarean section
16520-03Emergency lower segment caesarean section
16520-04Elective caesarean section, not elsewhere classified
16520-05Emergency caesarean section, not elsewhere classified
Denominator data elements:Help on this term
Data Element / Data Set

Episode of care—principal diagnosis, code (ICD-10-AM 10th edn) ANN{.N[N]}

Data SourceHelp on this term

Admitted Patient Care National Minimum Data Set (APC NMDS)

Data Element / Data Set

Episode of admitted patient care—procedure, code (ACHI 10th edn) NNNNN-NN

Data SourceHelp on this term

Admitted Patient Care National Minimum Data Set (APC NMDS)

Data Element / Data Set

Episode of care—additional diagnosis, code (ICD-10-AM 10th edn) ANN{.N[N]}

Data SourceHelp on this term

Admitted Patient Care National Minimum Data Set (APC NMDS)

Representational attributes

Representation class:Help on this termPercentage
Data type:Help on this termReal
Unit of measure:Help on this termPerson
Format:Help on this term

N[NN]

Data source attributes

Data sources:Help on this term
Data Source

Admitted Patient Care National Minimum Data Set (APC NMDS)

Frequency

Annual

Data custodian

Australian Institute of Health and Welfare

Source and reference attributes

Submitting organisation:Help on this term

Australian Commission on Safety and Quality in Health Care

Reference documents:Help on this term

Australian Commission on Safety and Quality in Health Care 2017. National Safety and Quality Health Service Standards. 2nd ed. Australian Commission on Safety and Quality in Health Care, Sydney. 

Australian Commission on Safety and Quality in Health Care 2021. Third and Fourth Degree Perineal Tears clinical care standard. Australian Commission on Safety and Quality in Health Care, Sydney.

 

<Title>

<body>
<footer>

View

  • Print view

Download

  • Word
  • PDF
  • Advanced options

Review

  • Compare items
Help
Downloading

The download may take a while, please wait.

Do not refresh the screen until the download is complete.

Terms & Conditions
Do you agree with the Terms and Conditions?

<Title>

<body>
<footer>
Loading...

Navigation

  • Find metadata
  • Metadata management
  • How to use METEOR
  • Learn about metadata

Resources

  • Accessibility
  • Copyright
  • Disclaimer
  • Freedom of Information
  • Privacy policy
  • Vulnerability and disclosure policy

Quick Links

  • Contact
  • FAQs
  • Search
AIHW logo
© Australian Insitute of Health and Welfware, 2023